This heat meter, when used with the sub-assemblies and configured as detailed below, has been independently verified by Kiwa GASTEC at CRE as suitably compliant with the Measuring Instruments Directive for the purposes of claiming the Renewable Heat Incentive.
Distributor:
DMS Flow Measurement & Controls Limited
Model qualifier:
with 449 Integrator
Meter specifications
MID accuracy class:
Class 2
Location of flow sensor:
Flow or return
Heat conveying liquid:
Water
Meter sub-assemblies:
Part number Pipe size Max flow rate qs (m3 /h) Nominal flow rate qp (m3 /h) Min flow rate qi (m3 /h) Max temp θmax (°C) Min temp θmin (°C) Min temp diff Δθmax (°C)
449-Qp0.6 110mm G3/4 G3/4 B (R1/2) 1.2 0.6 0.006 130 5 3
449-Qp1.5 110mm G3/4 G3/4 B (R1/2) 3 1.5 0.01 130 5 3
449-Qp1.5 130mm G1 G1 B (R3/4) 3 1.5 0.01 130 5 3
449-Qp1.5 190mm G1 G1 B (R3/4) 3 1.5 0.01 130 5 3
449-Qp2.5 130mm G1 G1 B (R3/4) 5 2.5 0.02 130 5 3
449-Qp2.5 190mm G1 G1 B (R3/4) 5 2.5 0.02 130 5 3
Additional notes
All Sontex equipment are calibrated sets.
In each Superstatic 449 kit you will get:-
1x Superstatic 449 flow part with display (can't disassemble)
1x Temperature sensors 460
They must never be separated due to the fact they are calibrated sets.
If a different display is used with a meter it is not suited for, this will in turn void all calibration certificates supplied. It will also mean you have an incorrect setup and the readings on the heat meter may be inaccurate.
Contact information
DMS Flow Measurement & Controls Limited
X-Cel House Chrysalis Way Langley Bridge Eastwood Nottinghamshire NG16 3RY UK
Return to meter database